May 5, 2021Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Artis zee ceiling-interventional Fluoroscopic X-Ray System Model Number: 10094137
Hazard: Some Artis zee ceiling systems show an increased abrasion of the cabling at the cable outlet of the inner C-arm, the limited functionality may not be sufficient to continue with treatment as planned. This may result in a situation where it is necessary to cancel clinical treatment or to continue treatment on an alternative system.
April 28, 2021Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Sensis/ Sensis Vibe Hemo systems with VD12A software as follows: Dedicated SIS Server- 6648153 Sensis Post-Processin
Hazard: Due to the configuration of certain Windows Service Permissions within the operating systems of the Sensis/ Sensis Vibe computer, there is a risk for exposure of sensitive information, manipulation of data, or Denial of Service attacks and could result in incorrect diagnostic or therapeutic decisions
April 14, 2021Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Ysio X.pree, Model Number: 11107464 - Product Usage: A Digital X-Ray System generate Xray images from the whole body in
Hazard: A patient image was assigned to a different patient during image recovery process. In the unlikely event of interrupted connection to a MAX detector during initiated image recovery, instead of the currently acquired image, previously acquired image (potentially image of the previous patient) may be displayed to the user, potentially impact diagnosis of the patient examined when the connection was interrupted
April 7, 2021Medical DevicesFDA
Siemens Medical Solutions USA, Inc. recalls Product Label - ACUSON Sequoia *** Power Input: 100-240V~, 13.0-5.4A, 50-60Hz *** (240)11148775 Model User Manual sta
Hazard: The ultrasound system averages the Mean Sac Diameter (MSD) and Gestational Sac Diameter (GSD) into the Estimated Date of Delivery (EDD) calculation. This may result in an incorrect EDD, which may influence patient management decisions regarding induction of labor and elective caesarean delivery, which may result in premature births.
March 31, 2021Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Interventional Fluoroscopic X-Ray System - Product Usage: developed for single and biplane diagnostic imaging and interv
Hazard: Siemens has become aware of a potential issue in which the imaging system UPS sporadically forces a shutdown of the imaging system PC without a true power supply problem.
March 24, 2021Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Software versions syngo.CT VA30A_SP2 or syngo.CT VA30A_SP2a in the Computed tomography systems as follows: SOMATOM go
Hazard: SOMATOM systems-issues in with software syngo.CT VA30A_SP2 or syngo.CT VA30A_SP2a, may result in sporadic problems causing scanning workflow interruptions and unexpected user notifications. Delay in diagnosis or patient rescan may occur. Sporadic software errors during interventional workflows may also result
March 10, 2021Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Sensis / Sensis Vibe systems with software version VD12 and equipped with HP Flex Pro-C PC. Diagnostic and administrati
Hazard: System may sporadically freeze (lock-up) during operation or while being in an idle state, no longer possible to interact with the system
March 3, 2021Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls ARTIS Icono biplane Model:11327600 ARTIS Icono floor system Model: 11327700 with software version VE20B - Product Usa
Hazard: Misleading error messages and a gap in the Operator Manual which affects ARTIS Icono biplane or ARTIS Icono floor systems with software version VE20B. Potential issues include System error management, Erroneous error messages, Zoom/Pan Function, Grid Indication, and Coolant Level. May cause procedures to be terminated and performed on an alternative x-ray system
January 20, 2021Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Uroskop Omnia Max, Model no. 10762473 - Product Usage: a solid state detector fluoroscopic X-ray system, primarily for u
Hazard: After the March 2019 corrective action on the monitor support arm, there is a residual risk of the support arm becoming dislodged in cases when the monitor support arm is used intensely over a long period of time.
January 20, 2021Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Uroskop Omnia, Model no. 10094910 - Product Usage: a solid state detector fluoroscopic X-ray system, primarily for urolo
Hazard: After the March 2019 corrective action on the monitor support arm, there is a residual risk of the support arm becoming dislodged in cases when the monitor support arm is used intensely over a long period of time.
January 20, 2021Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls SOMATOM Force, Definition AS, Definition Edge, Definition Flash, Drive, Confidence and Edge Plus
Hazard: System does not trigger a cancel command followed by a reload of the scan with the new parameter(s). This issue may result in a delay in diagnosis and/or need for patient rescan
January 20, 2021Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Artis zee/ zeego & Artis Q/ Q.zen Artis Pheno
Hazard: When the user changes frame rates from lower frequency (e.g. 10 f/s) to higher frequency (e.g. 30 f/s) during continuous release of Fluoro "Fluoro Override", the measured Air Kerma Rate can exceed the regulatory limits.
November 25, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Artis zee floor, Artis Q ceiling, Artis Q.zen ceiling. Image-Intensified Fluoroscopic X-Ray System. Material numbers 108
Hazard: Some electronic components within the generator were equipped with an incorrect protection diode. As a result, protection against overvoltage may be inadequate, and the system may not function properly in the event an overvoltage situation occurs.
November 11, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls ARTIS Icono Interventional Fluoroscopic X-Ray system - Product Usage: Intended Use: ARTIS is a family of dedicated angio
Hazard: There is a software problem which affects the DSA Roadmap application on ARTIS Icono and ARTIS Pheno systems with software version VE20B. In rare cases, when the DSA acquisition has been started while the C-Arm or table is moving, there may be a shift between the image acquired at the start position and the image (i.e. DSA vessel map) taken at the reference position. This may lead to a DSA vessel map being overlaid to a subtracted fluoro image at a position that is not accurate.. However, if the displacement is slight or at an unfavorable plane, the user might rely on incorrect visualization of the catheter relative to the vessel map. This could imply danger to the patient.
November 4, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Siemens Artis one systems with a Display Port transceiver-Fluoroscopic X-Ray System Model: 10848600 - Product Usage: he
Hazard: Potential malfunction in which the examination room monitor may become intermittently dysfunctional (e.g., no display/flicking/wrong resolution).
October 21, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Artis zee or Artis Q systems (listed below) - Product Usage: for single and biplane diagnostic imaging and interventiona
Hazard: Potential exists for the collision supervision not to work properly following loss of the individual room configuration data settings causing danger of collision with fix mounted room equipment, walls or floor may occur. This might cause components of the system to fall or tilt which could result in crushing of patients, operators or staff, collision of system parts with patients, as well as result in delay or interruption of the clinical procedure
October 14, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc. recalls ACUSON AcuNav Volume Intracardiac Echocardiography Catheter 12.5F
Hazard: Due to adverse events received by the firm for left atrial perforations and Atrioventricular Node block.
October 7, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Software versions syngo.CT VB20 or VB20_SP1 in the following systems: SOMATOM Force (Model #10742326) SOMATOM Definiti
Hazard: Sporadic problems with the current software may result in scanning workflow interruptions and unexpected user notifications causing delay in diagnosis or patient rescan
September 30, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Software: Syngo.via RT Image Suite software version VA30_SP02 with license T_RT_IMAGE_SUITE_PAT_MARK Intended Use: used
Hazard: Calibration offset between the central CT image plane and the external RT lasers has been set automatically to the factory default of 50.00 cm, if the misadjustment of the offset value is not recognized during the subsequent treatment planning process or remains undetected during the position verification at the treatment system (e.g. linear accelerator), this can potentially result in an incorrect dose or dose applied to the wrong location
September 9, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc. recalls Symbia S-Series and Symbia T-Series - Product Usage: Intended use of the device SPECT: To detect or image the distribu
Hazard: This letter is to inform you of the possibility that your Symbia S or Symbia T system(s) may have unintended slow motion of the detectors in specific situations which could pose a potential risk.
September 9, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Siemens Sensis Vibe Hemo system in combination with the MicroPodTM EtCO2 module-diagnostic and administrative tool suppo
Hazard: The connector linking the EtCO2 module to the HemoBox may break and become damaged, if the connector is re-attached to the HemoBox in this damaged state, under certain incorrect pin alignment conditions, the HemoBox may stop functioning and all vital signs are lost
September 2, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc. recalls E.cam or Symbia systems that use foresight detectors - Product Usage: To detect or image the distribution of radionuclid
Hazard: E. CAM and Symbia system with foresight detectors performing gated or dynamic acquisition may lose some detector time information. Our risk analysis indicates that the probability of occurrence is remote. SPECT: To detect or image the distribution of radionuclides in the body or organ, using the following techniques: planar imaging, whole body imaging, tomographic imaging for isotopes with energies up to 588keV. CT: The CT component is intended to produce cross sectional images of the body by computer reconstruction of x-ray transmission data from either the same axial place taken at different angles or spiral planes taken at different angles. SPECT+CT: Perform CT scans and nuclear imaging studies within the same instrument. To obtain attenuation corrected images and to provide registration of anatomical and physiological images within the patient's anatomy.
September 2, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Cios Spin, Image-Intensified Fluoroscopic X-Ray System The Cios Alpha and Cios Spin are a mobile X-Ray system designe
Hazard: Siemens has become aware of a hardware error which affects Cios Spin and Cios Alpha systems after the previous repair of the X-ray Generator with an integrated Energy Storage Unit (ESU).
September 2, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Cios Alpha, Image-Intensified Fluoroscopic X-Ray System The Cios Alpha and Cios Spin are a mobile X-Ray system design
Hazard: Siemens has become aware of a hardware error which affects Cios Spin and Cios Alpha systems after the previous repair of the X-ray Generator with an integrated Energy Storage Unit (ESU).
September 2, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls Cios Alpha (VA20) - Model: 10308191 Cios Alpha (VA30) - Model: 11105200 Cios Spin (VA30) - Model: 10308194 Cios Al
Hazard: Hardware error- Hot Plugging feature could cause an electrical malfunction on the main control D80 (below revision 04 installed) of the generator which is part of the main unit (c-arm) and cause permanent loss of imaging functionality.
August 12, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls SIEMENS Healthineers Ysio Max - Interventional Fluoroscopic X-Ray System, Model: 10762470 - Product Usage: is a device
Hazard: Two software issues (1) Using the override function in case of blocked system movements affecting Luminos dRF Max, Luminos Agile Max and Uroskop Omnia Max systems may cause collision of the system under operator control with obstacles or persons .(2) Incorrectly assigned image affecting Ysio Max, Luminos dRF Max and Luminos Agile Max systems with detector MAX Static causing incorrect base for diagnosis
August 12, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls SIEMENS Healthineers Uroskop Omnia max Model: 10762473 - Product Usage: is a device intended to visualize anatomical s
Hazard: Two software issues (1) Using the override function in case of blocked system movements affecting Luminos dRF Max, Luminos Agile Max and Uroskop Omnia Max systems may cause collision of the system under operator control with obstacles or persons .(2) Incorrectly assigned image affecting Ysio Max, Luminos dRF Max and Luminos Agile Max systems with detector MAX Static causing incorrect base for diagnosis
August 12, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls SIEMENS Healthineers Luminos Agile Max Model: 10762472 - Product Usage: is a device intended to visualize anatomical s
Hazard: Two software issues (1) Using the override function in case of blocked system movements affecting Luminos dRF Max, Luminos Agile Max and Uroskop Omnia Max systems may cause collision of the system under operator control with obstacles or persons .(2) Incorrectly assigned image affecting Ysio Max, Luminos dRF Max and Luminos Agile Max systems with detector MAX Static causing incorrect base for diagnosis
August 12, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls SIEMENS Healthineers Luminos dRF Max Model: 10762471- Product Usage: is a device intended to visualize anatomical stru
Hazard: Two software issues (1) Using the override function in case of blocked system movements affecting Luminos dRF Max, Luminos Agile Max and Uroskop Omnia Max systems may cause collision of the system under operator control with obstacles or persons .(2) Incorrectly assigned image affecting Ysio Max, Luminos dRF Max and Luminos Agile Max systems with detector MAX Static causing incorrect base for diagnosis
July 29, 2020Medical DevicesFDA
Siemens Medical Solutions USA, Inc recalls syngo.via RT Image Suite with software versions syngo.via VB30 or VB40
Hazard: If the user modifies for any reason (e.g. reduction of artifacts) the original image orientation of a standard MR protocol to acquire images in a different orientation for further processing in Synthetic CT , the software does not recognize the adapted acquisition plane. This may result in images with wrong geometry. When this distortion remains unnoticed and the images are subsequently exported to a treatment planning system (TPS), an incorrect calculated radiation treatment plan cannot be excluded. The occurence of this issue is very unlikely and has never been reported so far.